Harmony XALD XALK, Control station, plastic, dark grey lid, 1 green flush push button Ø22, spring return, marked START, 1 NO***EMAIL/TEXT FOR PRICING***

In stock
SKU: XALD103
Regular price $0.00 inc. GST

View Data Sheet

Specifications

Design

Range of product

Harmony XALD

Product or component type

complete control station

Product destination

for XB5 Ø 22 mm control and signalling units

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Cable entry

1 knock-out for cable entry, clamping capacity: 14-14 mm|2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12-12 mm

Net weight

0.156 kg

Mechanical durability

10000000 cycles

Connections - terminals

screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1|screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1

[ie] rated operational current

6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1|3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1|1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1|0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1|0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1|0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1

Electrical durability

1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C

Ambient air temperature for storage

-40...70 °C

Ambient air temperature for operation

-40...70 °C

Ip degree of protection

IP66 conforming to IEC 60529|IP67|IP69|IP69K

Ik degree of protection

IK03 conforming to EN 50102

Standards

EN/IEC 60947-5-4|CSA C22.2 No 14|EN/IEC 60947-5-1|UL 508|EN/IEC 60947-1|JIS C8201-5-1|EN/IEC 60947-5-5|JIS C8201-1

Reach regulation

Free of Substances of Very High Concern above the threshold

Reach free of svhc

Yes

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1806010EN

Circularity profile

ENVEOLI1806010EN

Material

Material

polycarbonate

Contacts material

silver alloy (Ag/Ni)

Others

Package 1 bare product quantity

1

Device short name

XALD

Control station application

start function

Colour of base of enclosure

light grey (RAL 7035)

Colour of cover

dark grey (RAL 7016)

Operator profile

1 flush push-button

Operators description

green ''START'' 1 NO

Control station composition

1 flush push-button, green 1 NO START marking

Marking location

marking on push-button

Contact operation

slow-break

Resistance to high pressure washer

7000000 Pa at 55 °C, distance : 0.1 m

Colour of marking

white marking when green, red or black caps|black marking when white caps

Positive opening

without

Operating travel

2.6 mm (NO changing electrical state)|4.3 mm (total travel)

Operating force

3.8 N NO changing electrical state

Tightening torque

0.8...1.2 N.m conforming to EN/IEC 60947...1

Shape of screw head

cross compatible with Philips no 1 screwdriver|cross compatible with pozidriv No 1 screwdriver|slotted compatible with flat Ø 4 mm screwdriver|slotted compatible with flat Ø 5.5 mm screwdriver

Short-circuit protection

10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1

[ith] conventional free air thermal current

10 A conforming to EN/IEC 60947-5-1

[ui] rated insulation voltage

600 V (pollution degree 3) conforming to EN/IEC 60947-1

[uimp] rated impulse withstand voltage

6 kV conforming to EN/IEC 60947-1

Electrical reliability

? < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4|? < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4

Compatibility code

XALD

Protective treatment

TH

Overvoltage category

class II conforming to IEC 60536

Nema degree of protection

NEMA 13|NEMA 4X

Vibration resistance

5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6

Shock resistance

30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27|50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

7.0 cm

Package 1 width

7.0 cm

Package 1 length

9.8 cm

Package 1 weight

136.0 g

Unit type of package 2

S03

Number of units in package 2

40

Package 2 height

30.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

5.997 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins