EcoStruxure I/O Smart Link, Communication Module, Modbus, RS485***EMAIL/TEXT FOR PRICING***

In stock
SKU: A9XMSB11
Regular price $0.00 inc. GST

View Data Sheet

Specifications

Design

Range of product

Acti9

Range

EcoStruxure

Product or component type

smart communication module

Device application

load control|breaker status monitoring|basic energy metering E

Market segment

buildings|small commercial

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Protection type

against reverse polarity for auxiliary supply|against reverse polarity for input|overvoltage at 33 V DC for digital output

Inrush current

0.5 A for digital output|7 A for power supply

Local signalling

communication: 1 LED (yellow)|status: 1 LED (green, orange and red)

Type of setting

Modbus address 01...99 for address encoders|reset for address encoders|reset for plug in, plug out the auxiliary supply

Mounting position

horizontal and vertical on DIN rail

Connections - terminals

spring-loaded terminal Ti24 qty: 11 for digital input/output, ordered separately|plug-in connector qty: 1 for supply circuit|plug-in connector qty: 1 for communication bus

Clamping connection capacity

2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible with cable end for communication bus|2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, flexible without cable end for communication bus|2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid with cable end for communication bus|2 x 0.2...2 x 1.5 mm² for twisted shielded pairs cable, rigid without cable end for communication bus|1 x 0.2...1 x 1.5 mm², flexible with cable end for control|1 x 0.2...1 x 1.5 mm², flexible without cable end for control|1 x 0.2...1 x 1.5 mm², rigid with cable end for control|1 x 0.2...1 x 1.5 mm², rigid without cable end for control|2 x 0.2...2 x 1.5 mm², flexible with cable end for supply circuit|2 x 0.2...2 x 1.5 mm², flexible without cable end for supply circuit|2 x 0.2...2 x 1.5 mm², rigid with cable end for supply circuit|2 x 0.2...2 x 1.5 mm², rigid without cable end for supply circuit

Wire stripping length

control: 10 mm|supply circuit: 7 mm|communication bus: 7 mm

Communication network type

RS485 Modbus RTU client/server SUB-D 9 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps

Height

22.5 mm

Width

359 mm

Depth

42 mm

Net weight

188 g

Provided equipment

set of 1 bus connector|set of 1 power supply connector|set of 2 locking clips

Range compatibility

Acti 9 iTL auxiliary|Linergy Linergy FM|Acti 9 iOF+SD 24|Acti 9 iACT24|Acti 9 iATL24|PowerLogic pulse output meter|Acti 9 RCA iC60|Acti 9 Acti9 iCT auxiliary|Acti 9 Acti9 iC60|Acti 9 Acti9 iID|Acti 9 Acti9 iSW-NA|Acti 9 Acti9 iDPN Vigi|Acti 9 Acti9 C40|Multi9 Multi9 C60|Acti 9 Acti9 DT40|Acti 9 Acti9 DT60|Acti 9 Acti9 I-NA|Acti 9 Acti9 ITG40|Acti 9 Acti9 iDPN|Acti 9 Acti9 Reflex iC60 Ti24 connector

Ip degree of protection

IP20

Ik degree of protection

IK06 conforming to IEC 62262

Environmental characteristic

corrosive 3C2 conforming to IEC 60721-3-3|salt mist 2 conforming to IEC 60068-2-52

Relative humidity

0...93 % at 40 °C

Ambient air temperature for operation

-25...60 °C

Ambient air temperature for storage

-40...85 °C

Standards

IEC 61010-2-201|IEC 61010-1

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP120426EN

Circularity profile

ENVEOLI120412EN

Others

Package 1 bare product quantity

1

Package 2 bare product quantity

32

Product name

EcoStruxure I/O Smart Link

Device short name

I/O Smart Link

Connected auxiliaries

up to 11 wired devices

Group of channels

1 group of 11 digital channels

Maximum supply current

1.5 A

[us] rated supply voltage

24 V DC +/- 20 %

Connectivity to devices

digital input and output|pulse output meter

Communication service

Modbus server for RS485

Web server

BMS controller compatible

Web services

web page

Application specific i/o

pulse totalising counter|pulse converter

Immunity to microbreaks

10 ms

Reset

factory reset on front face|by booted push-button|by address encoder|by plug in, plug out the power supply

Input/output type

2 inputs + 1 output per digital channel

Input type

current sink for digital input, 24 V DC +/- 20 % at 2.5 mA

Maximum permanent current

5 mA for digital input

Electronic filtering time

2 ms for digital input from state 0 to state 1

Output type

logic current source: 24 V - DC - 100 mA

Maximum voltage drop

<1 V at state 1 digital output

Location of connection

front

9 mm pitches

0 useful

Commissioning interface

EcoStruxure Power Commission|web page

Compatibility code

Acti 9 Smartlink

Pollution degree

3

Electromagnetic compatibility

resistance to electrostatic discharge (air discharge), class B, 8 kV, conforming to IEC 61000-4-2|resistance to electrostatic discharge (contact discharge), class B, 4 kV, conforming to IEC 61000-4-2|resistance to radiated electromagnetic fields (80 MHz...3 GHz), class A, 10 V/m, conforming to IEC 61000-4-3|power supply: resistance to radiated electromagnetic fields (1.4…6 GHz), class A, 3 V/m, conforming to IEC 61000-4-3|power supply: resistance to fast transient (5...100 kHz), class B, 2 kV, conforming to IEC 61000-4-4|input/output: resistance to fast transient, class B, 1 kV, conforming to IEC 61000-4-4|communication bus: resistance to fast transient (0.15...80 MHz), class B, 1 kV, conforming to IEC 61000-4-4|conducted EMC (0.15...80 MHz), class A, 3 V, conforming to IEC 61000-4-6|conducted emission (0.15...30 MHz), class B, conforming to IEC 61326-1|conducted emission (0.15...30 MHz), class B, conforming to CISPR 11|radiated emission (30...6000 MHz), class B, conforming to IEC 61326-1|radiated emission (30...6000 MHz), class B, conforming to CISPR 11|power supply: surges (DM coupling 42 Ohm), class B, 1 kV, conforming to IEC 61000-4-5|power supply: surges (CM coupling 42 Ohm), class B, 2 kV, conforming to IEC 61000-4-5|communication bus: surges (CM coupling 2 Ohm), class B, 1 kV, conforming to IEC 61000-4-5

Vibration resistance

1 gn, amplitude = 3.5 mm (f = 5-300 Hz)10 cycles conforming to EN/IEC 60068-2-6

Shock resistance

15 gn for 11 ms conforming to IEC 60068-2-27

Fire resistance

other parts: 650 °C ( 30 s ) conforming to IEC 60695-2-10|on connection terminals: 960 °C ( 30 s ) conforming to IEC 60695-2-10

Tropicalisation

2

Operating altitude

0...2000 m

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

3.4 cm

Package 1 width

6.4 cm

Package 1 length

36.4 cm

Package 1 weight

271.0 g

Unit type of package 2

S03

Number of units in package 2

32

Package 2 height

30.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

9.063 kg