TeSys GV2, Motor circuit breaker,TeSys Deca,3P,6-10A,thermal magnetic,screw clamp terminals,toggle handle***EMAIL/TEXT FOR PRICING***

In stock
SKU: GV2RT14
Regular price $0.00 inc. GST

View Data Sheet

Specifications

Design

Range

TeSys Deca

Range of product

TeSys GV2

Product or component type

motor circuit breaker

Device application

motor protection|motor

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Fixing mode

35 mm symmetrical DIN rail: clipped|panel: screwed (with adaptor plate)

Control type

toggle

[in] rated current

10 A

[ue] rated operational voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

Mechanical durability

100000 cycles

Electrical durability

100000 cycles for AC-3 at 415 V In|100000 cycles for AC-3e at 415 V In

Width

45 mm

Height

89 mm

Depth

78.5 mm

Standards

EN/IEC 60947-2|EN/IEC 60947-4-1

Product certifications

CCC|UL|CSA|EAC|LROS (Lloyds register of shipping)|BV|UKCA

Ik degree of protection

IK04

Ip degree of protection

IP20 conforming to IEC 60529

Climatic withstand

conforming to IACS E10

Ambient air temperature for storage

-40...80 °C

Ambient air temperature for operation

-20...60 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Environmental disclosure

ENVPEP121004

Circularity profile

ENVEOLI121004

California proposition 65

WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov

Others

Package 1 bare product quantity

1

Product name

TeSys GV2|TeSys Deca

Device short name

GV2RT

Trip unit technology

thermal-magnetic

Poles description

3P

Network type

AC

Utilisation category

category A conforming to IEC 60947-2|AC-3 conforming to IEC 60947-4-1|AC-3e conforming to IEC 60947-4-1

Network frequency

50/60 Hz conforming to IEC 60947-4-1

Motor power kw

1.5...1.5 kW at 220/230 V AC 50/60 Hz motor protection high peak current|2.2.2 kW at 220/230 V AC 50/60 Hz motor protection high peak current|3 kW at 400/415 V AC 50/60 Hz motor protection high peak current|4 kW at 400/415 V AC 50/60 Hz motor protection high peak current|4 kW at 440 V AC 50/60 Hz motor protection high peak current|4 kW at 500 V AC 50/60 Hz motor protection high peak current|5.5.5 kW at 500 V AC 50/60 Hz motor protection high peak current|5.5.5 kW at 690 V AC 50/60 Hz motor protection high peak current|7.5...7.5 kW at 690 V AC 50/60 Hz motor protection high peak current|2.5...2.5 kW at 230/240 V AC 50/60 Hz transformer protection|4 kW at 400/415 V AC 50/60 Hz transformer protection|5 kW at 400/415 V AC 50/60 Hz transformer protection|5 kW at 440 V AC 50/60 Hz transformer protection|5 kW at 500 V AC 50/60 Hz transformer protection|6.3...6.3 kW at 500 V AC 50/60 Hz transformer protection

Breaking capacity

100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2|100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2|15 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2|10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2|3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2

Thermal protection adjustment range

6...10 A conforming to IEC 60947...4-1

Magnetic tripping current

200 A

[ith] conventional free air thermal current

10 A conforming to IEC 60947-4-1

[ui] rated insulation voltage

690 V AC 50/60 Hz conforming to IEC 60947-2

[uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-2

Suitability for isolation

yes conforming to IEC 60947-1 § 7-1-6

Power dissipation per pole

2.5 W

Maximum operating rate

25 cyc/h

Rated duty

continuous conforming to IEC 60947-4-1

Direct connector

without

Tightening torque

1.7 N.m - on screw clamp terminal

Compatibility code

GV2RT

Fire resistance

960 °C conforming to IEC 60695-2-11

Mechanical robustness

shocks: 30 Gn for 11 ms|vibrations: 5 Gn, 5...150 Hz

Operating altitude

2000 m

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

4.7 cm

Package 1 width

9.5 cm

Package 1 length

8.5 cm

Package 1 weight

278 g

Unit type of package 2

S02

Number of units in package 2

24

Package 2 height

15 cm

Package 2 width

30 cm

Package 2 length

40 cm

Package 2 weight

6.953 kg

Unit type of package 3

P06

Number of units in package 3

288

Package 3 height

75 cm

Package 3 width

60 cm

Package 3 length

80 cm

Package 3 weight

92.872 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show less

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)