Arc Fault Detection (AFDD+RCBO)***EMAIL/TEXT FOR PRICING***

In stock
SKU: MX9A3220
Regular price $0.00 inc. GST

View Data Sheet

Specifications

Design

Range

MAX9

Product or component type

arc fault detection RCBO

Sustainable offer status

Green Premium product

Warranty

7-year

Physical

Standards

EN/IEC 62606|AS/NZS 61009.1

[in] rated current

20 A at 30 °C

[ue] rated operational voltage

240 V AC 50 Hz conforming to AS/NZS 61009.1

Control type

toggle

Local signalling

ON, OFF, fault trip

Mounting mode

clip-on

Mounting support

DIN rail

Mechanical durability

20000 cycles

Electrical durability

10000 cycles AC 50 Hz conforming to IEC 61009

Connections - terminals

tunnel type terminal top or bottom 1-10 mm² flexible|tunnel type terminal top or bottom 1-16 mm² rigid

Wire stripping length

14 mm for top or bottom connection

Height

91 mm

Width

36 mm

Depth

75 mm

Net weight

237 g

Ip degree of protection

IP20

Relative humidity

95 % at 55 °C

Ambient air temperature for operation

-25...70 °C

Ambient air temperature for storage

-40...85 °C

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Compliant with Exemptions

Mercury free

Yes

China rohs regulation

Product out of China RoHS scope. Substance declaration for your information

Rohs exemption information

Yes

Environmental disclosure

ENVPEP2205013EN

Circularity profile

ENVEOLI2205013EN

Others

Package 1 bare product quantity

1

Circuit breaker application

distribution

Product specific application

fire prevention by arc detection

Poles description

1P + N

Number of protected poles

1

Curve code

C

Breaking capacity

6000 A Icn at 240 V AC 50 Hz conforming to AS/NZS 61009.1

Earthing system

TN-S|TT|IT

Earth-leakage sensitivity

30 mA

Network type

AC

Earth-leakage protection time delay

instantaneous

Earth-leakage protection class

type A

Neutral position

left

Suitability for isolation

yes

Trip unit technology

thermal-magnetic

Earth-leakage protection

integrated

Network frequency

50 Hz

Device location in system

outgoer

Magnetic tripping limit

5...10 x In

[ics] rated service breaking capacity

6000 A at 240 V AC 50 Hz conforming to AS/NZS 61009.1

Rated breaking and making capacity

500 A

Limitation class

3

[ui] rated insulation voltage

440 V AC 50 Hz

Threshold tripping voltage

275 V

[uimp] rated impulse withstand voltage

4 kV conforming to AS/NZS 61009.1

Contact position indicator

yes

Overvoltage category

III

Locking options description

by padlocks

Tightening torque

2 N.m top or bottom

Comb busbar and distribution block compatibility

top comb busbar: YES

Connection pitch

9 mm between phase and neutral

9 mm pitches

4

Targeted country

Australia

Temperature derating table

-25 °C ( 23.8 A ) |-20 °C ( 23.5 A ) |-15 °C ( 23.2 A ) |-10 °C ( 22.8 A ) |-5 °C ( 22.5 A ) |0 °C ( 22.2 A ) |5 °C ( 21.8 A ) |10 °C ( 21.5 A ) |15 °C ( 21.1 A ) |20 °C ( 20.7 A ) |25 °C ( 20.4 A ) |30 °C ( 20 A ) |35 °C ( 19.6 A ) |40 °C ( 19.2 A ) |45 °C ( 18.8 A ) |50 °C ( 18.4 A ) |55 °C ( 18 A ) |60 °C ( 17.6 A ) |65 °C ( 17.1 A ) |70 °C ( 16.7 A )

Grid distance

35 mm

Heat dissipation

4.7...4.7 W at 240 V - 20 A

Pollution degree

2

Tropicalisation

severity B conforming to IEC 60068-2-30 for 28 d

Operating altitude

0...2000 m

Quality labels

RCM

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8.4 cm

Package 1 width

4.4 cm

Package 1 length

10.2 cm

Package 1 weight

236.0 g

Unit type of package 2

CAR

Number of units in package 2

40

Package 2 height

20.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

9.94 kg
Show less

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)