Harmony XALD XALK, Control station, plastic, dark grey lid, 1 green flush push button Ø22, spring return, marked START, 1 NO***EMAIL/TEXT FOR PRICING***

有存货
存货单位: XALD103
正常价格 $0.00 公司消费税

View Data Sheet

Specifications

Design

Range of product

Harmony XALD

Product or component type

complete control station

Product destination

for XB5 Ø 22 mm control and signalling units

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Cable entry

1 knock-out for cable entry, clamping capacity: 14-14 mm|2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12-12 mm

Net weight

0.156 kg

Mechanical durability

10000000 cycles

Connections - terminals

screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1|screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1

[ie] rated operational current

6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1|3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1|1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1|0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1|0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1|0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1

Electrical durability

1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C|1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C

Ambient air temperature for storage

-40...70 °C

Ambient air temperature for operation

-40...70 °C

Ip degree of protection

IP66 conforming to IEC 60529|IP67|IP69|IP69K

Ik degree of protection

IK03 conforming to EN 50102

Standards

EN/IEC 60947-5-4|CSA C22.2 No 14|EN/IEC 60947-5-1|UL 508|EN/IEC 60947-1|JIS C8201-5-1|EN/IEC 60947-5-5|JIS C8201-1

Reach regulation

Free of Substances of Very High Concern above the threshold

Reach free of svhc

Yes

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Toxic heavy metal free

Yes

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP1806010EN

Circularity profile

ENVEOLI1806010EN

Material

Material

polycarbonate

Contacts material

silver alloy (Ag/Ni)

Others

Package 1 bare product quantity

1

Device short name

XALD

Control station application

start function

Colour of base of enclosure

light grey (RAL 7035)

Colour of cover

dark grey (RAL 7016)

Operator profile

1 flush push-button

Operators description

green ''START'' 1 NO

Control station composition

1 flush push-button, green 1 NO START marking

Marking location

marking on push-button

Contact operation

slow-break

Resistance to high pressure washer

7000000 Pa at 55 °C, distance : 0.1 m

Colour of marking

white marking when green, red or black caps|black marking when white caps

Positive opening

without

Operating travel

2.6 mm (NO changing electrical state)|4.3 mm (total travel)

Operating force

3.8 N NO changing electrical state

Tightening torque

0.8...1.2 N.m conforming to EN/IEC 60947...1

Shape of screw head

cross compatible with Philips no 1 screwdriver|cross compatible with pozidriv No 1 screwdriver|slotted compatible with flat Ø 4 mm screwdriver|slotted compatible with flat Ø 5.5 mm screwdriver

Short-circuit protection

10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1

[ith] conventional free air thermal current

10 A conforming to EN/IEC 60947-5-1

[ui] rated insulation voltage

600 V (pollution degree 3) conforming to EN/IEC 60947-1

[uimp] rated impulse withstand voltage

6 kV conforming to EN/IEC 60947-1

Electrical reliability

? < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4|? < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4

Compatibility code

XALD

Protective treatment

TH

Overvoltage category

class II conforming to IEC 60536

Nema degree of protection

NEMA 13|NEMA 4X

Vibration resistance

5 gn (f= 12-500 Hz) conforming to IEC 60068-2-6

Shock resistance

30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27|50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

7.0 cm

Package 1 width

7.0 cm

Package 1 length

9.8 cm

Package 1 weight

136.0 g

Unit type of package 2

S03

Number of units in package 2

40

Package 2 height

30.0 cm

Package 2 width

30.0 cm

Package 2 length

40.0 cm

Package 2 weight

5.997 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show less

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)