Harmony XB5R, Relay Antenna, AC/DC, 5m cable output***EMAIL/TEXT FOR PRICING***

有存货
存货单位: ZBRA1
正常价格 $0.00 公司消费税

View Data Sheet

Specifications

Design

Range of product

Harmony XB5R

Product or component type

wireless and batteryless range

Product destination

Wireless Schneider Electric ecosystem devices

Sustainable offer status

Green Premium product

Warranty

18 months

Physical

Transmission frequency

2405 MHz for transmitter|2405 MHz for receiver

Communication port protocol

Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4

Number of channels

1

Net weight

0.2 kg

Ambient air temperature for storage

-40...70 °C

Relative humidity

90 % at -20...55 °C, without condensation conforming to ETSI EN 300 440...1

Ip degree of protection

IP65 conforming to IEC 60529 55 °C 0.1 m

Ik degree of protection

IK03 conforming to IEC 62262

Product certifications

CCC|BT 2006/95/EC|UL|GOST|CSA|CE|C-Tick

Insulation resistance

> 500 MOhm at 500 V DC conforming to NF C 20030

Reach regulation

Reference contains Substances of Very High Concern above the threshold

Eu rohs directive

Pro-active compliance (Product out of EU RoHS legal scope)

Mercury free

Yes

Rohs exemption information

Yes

China rohs regulation

X

Environmental disclosure

ENVPEP101106EN

Circularity profile

ENVEOLI1103010EN

California proposition 65

WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Material

Material

polycarbonate

Others

Package 1 bare product quantity

1

Device short name

ZBRA

Control station application

transceiver (emission and reception)

Colour of base of enclosure

black (RAL 9011)

Colour of cover

transparent

Level or class

5M00G7W

Antenna type

omnidirectional

Antenna gain

0 dBi

Maximum sensing distance

300 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna

Emission power

3 mW

[us] rated supply voltage

24...240 V AC/DC 50/60 Hz - 10...10 %

Maximum power consumption in w

4 W AC/DC

Operating position

vertical

Status led

1 LED green for power ON|1 LED green for emission signal

Overvoltage category

III conforming to IEC 60664-1

Rated short-duration power frequency withstand voltage

4 kV 50 Hz conforming to IEC 60947-5-1

[uimp] rated impulse withstand voltage

4 kV

Electrical connection

2 conductors cable 0.34-0.34 mm² - flexible - 5 m conforming to IEC 60947-1

Tightening torque

0.6...0.6 N.m conforming to IEC 60947...1

Housing material

self-extinguishing plastic

Short-circuit protection

0.4 A fuse type fast blow

Max power consumption in w

1 mW

Modulation technique

O-QPSK

Bandwidth

5 MHz

Cad overall height

67 mm

Cad overall width

93 mm

Electrical shock protection class

class II conforming to IEC 61140

Pollution degree

3 conforming to IEC 60664-1

Radio agreement

RSS|SRRC|ANATEL, type III conforming to ETSI EN 301 489-3|ARIB T66, class 2 conforming to ETSI EN 301 489-3|FCC, category 2 conforming to ETSI EN 300 440-1|ICASA, category 1 conforming to ETSI EN 300 440-1

Directives

1999/5/EC - R&TTE directive|2004/108/EC - electromagnetic compatibility

Vibration resistance

+/-0.5 mm (f= 10-55 Hz) conforming to IEC 60068-2-6|6 gn (f= 55-150 Hz) conforming to IEC 60068-2-6

Shock resistance

25 gn (duration = 6 ms) for 6000 shocks conforming to IEC 60068-2-27|15 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

[ui] rated insulation voltage

250 V conforming to IEC 60664-1

Electromagnetic compatibility

immunity for industrial environments conforming to IEC 61000-6-2|conducted and radiated emissions class B conforming to CISPR 22|electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2|electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2|susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3|susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3|electrical fast transient/burst immunity test - test level: 2 kV conforming to IEC 61000-4-4|1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5|1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5|conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6|immunity to microbreaks and voltage drops conforming to IEC 61000-4-11|radiated emission conforming to ETSI EN 300 440-1|conducted emission conforming to EN 300-489-1|conducted emission conforming to ETSI EN 300 489-3|radiated emission conforming to ETSI EN 300 440-2

Unit type of package 1

PCE

Number of units in package 1

1

Package 1 height

8.000 cm

Package 1 width

8.000 cm

Package 1 length

18.700 cm

Package 1 weight

267.000 g

Unit type of package 2

S03

Number of units in package 2

18

Package 2 height

30.000 cm

Package 2 width

30.000 cm

Package 2 length

40.000 cm

Package 2 weight

5.293 kg

Weee

The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
Show less

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)